4
Bollente trutankless® VERO Series Water Heaters www.trutankless.com
HEATING AND ALERT INDICATORS
G
/
L
F/ C
O O
GPM
LPM
O
F
O
F
O
C
O
F
O
C
O
C
A, B, CD
A.) Heating mode: the heating icon is illuminated
B.) Lockout mode: the heating icon is blinking slowly
C.) Anti-freeze mode: the heating icon is blinking rapidly
D.) Any alarm: the alert icon is illuminated
FREEZE GUARD PROTECTION MODE
e VERO BR/BC trutankless Residential & Commercial Water Heater is designed such that, should the water temperature at
either the inlet or outlet cool to 41°F (5°C), the heater automatically warms the water to approximately 45°F (7°C). is cycle
will continue for as long as the unit experiences temperatures near the freezing point.
If the main power to the heater is o, the freeze guard protection feature will not operate. e freeze protection circuit
protects the heater only and is not sucient protection for water connections to and from the heater, including the Flow
Sensor and other optional devices. Any damage to the heater caused by freezing is not covered by warranty as it is the
responsibility of the user to ensure the heater is installed in an environment protected from freezing.
LEAK SENSOR
A leak sensor is built into the controller circuitry on the interconnect module and activates if it senses a leak with a ow
greater than .05 GPM. When this happens, the controller starts an audible alarm, displays an on-screen message, sends an
alert, if desired, and disconnects the power within the VERO BR/BC unit. When power is disconnected within the heater it
will not heat water. is option is particularly useful in condominium or high-rise applications where damage from ooding
can be signicant. Normal condensation will not trigger an alert.
TECHNICAL DATA
MODEL PARAMETERS
Model BC BR
Voltage 208 VAC 220-240 VAC
Amperage 60-160 A 60-160 A
Power 12.5-33.3 kW 13.2-36.0 kW
Flow 0.2-10 GPM 0.2-10 GPM
Phase Single, 60 Hz Single, 50/60 Hz
Max Temperature 180°F (82.2°C) 140°F (60°C)