Installation and Operation Guide
www.trutankless.com Bollente trutankless® VERO Series Water Heaters
17
Conrm that the cold water supply main is turned on and that main power is connected to the unit.
Replace the outer cover of the unit by lining up the cutouts with their corresponding pipe connectors, etc., and sliding it
into place. Tighten the four (4) truss head screws (two at bottom of unit and two at top) until comfortably snug. Do not over
tighten.
Only now is trutankless VERO BR/BC Water Heater ready for power-up and conguration.
IMPORTANT: Ideal performance of the trutankless system depends on compliance with
properly setting the DIP switch positions. The DIP switch positions determine the performance
parameters of the unit model. To ensure proper installation and system operation, the unit MUST
be congured using the DIP switches settings specied in Table 2 on Page 9 and pictured in
Table 3 on page 10. Following these instructions and properly setting the DIP switches at
installation is extremely critical to the proper functioning of the system and will ensure
ideal temperature rise and ow rate maximums.
Switch ON the main power circuit breakers.
Switch ON the trutankless unit circuit breakers.
e controller powers up and the LCD screen displays the Startup screen for approximately 4 seconds.
Next, open a hot water tap inside the building with a minimum ow of one (1) gallon (3.8 liters) per minute and allow it to
ow for a minimum of two (2) minutes to purge air from the heating chamber and protect the unit from dry re.
NOTE: e trutankless VERO BR/BC unit must sense active water ow before it will allow the elements to heat. e LCD
screen will be in lockout mode for a period of 120 seconds (2 minutes) while the water lls the heating tubes completely and
the startup sequence completes.
is completes the installation procedure. e trutankless Water Heater is now in service. Operation is as simple as opening
a hot water tap. e unit will then begin heating water and can typically reach the set-point temperature in as little as 15-30
seconds.
NOTE: Remember that water already in the supply line may be cold, so it may take somewhat longer for the hot water to reach
the faucet.
Upon closing the hot water tap, the unit automatically returns to standby mode. at’s all there is to operating your
trutankless VERO BR/BC Water Heater!