18
Bollente trutankless® VERO Series Water Heaters www.trutankless.com
trutankless VERO BR/BC units have been designed to be maintenance-free*, yet periodic system checks are
recommended.
*In areas where the water hardness exceeds 180 PPM or 10.5 grains/gallons, a water soener or lter needs to be installed
and system checks, particularly of sedimentation accumulation in the ow sensor, should be carried out annually. Failure to
install a ltration or soening system in areas with very hard water voids this warranty completely.
WARNING: Always turn off the power circuit breakers at BOTH the main electrical
panel and at the unit access panel! High voltage is present in the system. Personal
injury or death can result if caution is not taken!
e following items should be checked at each inspection:
• Flow Sensor (paddle wheel clear of any sediment)
• Breakers (corrosion)
• Inlet pipe connection (is it tight and dry?)
• Outlet pipe connection (is it tight and dry?)
• Flush Pipe Connection (is it tight and dry?)
• Surrounding heater – Clean and free of dust and debris
In case of an error message from the trutankless VERO BR/BC Water Heater, turn o all the hot water faucets. Wait for one
minute. Turn a hot water faucet back on. If the error message persists, call your licensed contractor or authorized service
technician. Do not attempt to self-service the unit!
ITEM RESIDENTIAL COMMERCIAL
1 4 DIN Mount Circuit Breakers (63A Rating) 4 DIN Mount Circuit Breakers (63A Rating)
2 4 Traics 8 Traics
3 240V 9000W Element 208V 9000W Element
4 158°F (70°C) Thermal Cutout Switch 197.6°F (92°C) Thermal Cutout Switch
SAFETY NOTE: Commercial units are designed for commercial settings, and can be set as high as 180°F (82° C) for industrial
processes including sterilization of quipment and untensils. EXTREME CARE should be taken when setting temperatures higher than
140°F( 60°C), such temperatures should not be directly used in the shower, there is risk of burns.
Hot Water Scald Burn Warning for Infants, Children, & Elderly: Great care must be taken when exposing infants or children to warm