VX-110 OPERATING MANUAL34
Set Mode
Set Item 18
[
MON/TCL
]
Function: Select the MONI key (just below the PTT switch) function.
Available Values: MONI/T.CALL
Default: Depends on the transceiver version.
MONI: Pressing the MONI key causes the noise/tone Squelch to be over-ridden, allow-
ing you to listen for weak (or non-encoded) signals.
T.CALL: Pressing the MONI key activates a 1750-Hz burst tone, used for repeater access
in many countries.
Set Item 19
[
LMP MOD
]
Function: Select the LCD/Keypad Lamp mode.
Available Values: KEY/5SEC/TOGGLE
Default: KEY
Set Item 20
[
TOT
]
Function: Set the TOT (Time-Out Timer) time.
Available Values: OFF/1 min/2.5 min/5 min/10 min
Default: OFF
Set Item 21
[
BCLO
]
Function: Enable/disable the Busy Channel Lock-Out feature.
Available Values: ON/OFF
Default: OFF
Set Item 22
[
CLK SFT
]
Function: Shifting of CPU clock frequency.
Available Values: ON/OFF
Default: OFF
This function is only used to move a spurious response “birdie” should it fall on a desired
frequency.
Set Item 23
[
SQL TYP
]
Function: Select the Tone Encoder and/or Decoder mode.
Available Values: OFF/T/TSQ/DCS
Default: OFF
T: CTCSS Encoder
TSQ: CTCSS Encoder/Decoder
DCS: Digital Coded Squelch Encoder/Decoder