EasyManuals Logo

Vesper Cortex M1 User Manual

Vesper Cortex M1
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
30
LIGHT
GREEN
BROWN
GRAY
VIOLET
BLUE
BLACK
INPUT 3
INPUT 2
INPUT 1
GPIO GND
-ve-ve
Output relay
Light
+ve 12/24V
NO
C
LIGHT
GREEN
BROWN
GRAY
VIOLET
BLUE
BLACK
INPUT 3
INPUT 2
INPUT 1
GPIO GND
LIGHT
GREEN
BROWN
GRAY
VIOLET
BLUE
INPUT 3
INPUT 2
INPUT 1
C
-ve
Magnetic reed switch
SMOKE / HEAT DETECTOR
LIGHT
GREEN
BROWN
GRAY
VIOLET
BLUE
BLACK
RED
I/O 2
I/O 1
INPUT 3
INPUT 2
INPUT 1
GPIO GND
EXTERNAL V IN
-ve
LIGHT
GREEN
BROWN
GRAY
VIOLET
BLUE
BLACK
RED
I/O 2
I/O 1
INPUT 3
INPUT 2
INPUT 1
GPIO GND
EXTERNAL V IN
CANVAS SNAP SENSOR
-ve
BASE SENSOR
SNAP
BILGE PUMP
-ve
+ve 12/24V
+ve 12/24V
MOTION SENSOR
-ve
LIGHT
GREEN
BROWN
GRAY
VIOLET
BLUE
BLACK
RED
I/O 2
I/O 1
INPUT 3
INPUT 2
INPUT 1
GPIO GND
EXTERNAL V IN
EXTERNAL SENSOR
-ve
-ve
OUTPUT RELAY
LIGHT
+ve 12/24V
+ve 12/24V
NO
-
C
+
LIGHT
GREEN
BROWN
GRAY
VIOLET
BLUE
BLACK
RED
I/O 2
I/O 1
INPUT 3
INPUT 2
INPUT 1
GPIO GND
EXTERNAL V IN
EXTERNAL SENSOR
-ve
-ve
OUTPUT RELAY
LIGHT
+ve 12/24V
+ve 12/24V
NO
-
C
+
V + V -
C
NC
-ve
MAGNETIC REED SWITCH
-ve
-ve
HIGH WATER SENSOR
-ve
BILGE PUMP
-ve
+ve 12/24V
+
-
add system voltage and
connect pullp
add pullup to system voltage
NO
RED
PULLUP
VOLTAGE
-ve
RED
PULLUP
VOLTAGE
+ve -ve
+ve 12/24V
LIGHT
GREEN
BROWN
GRAY
VIOLET
BLUE
BLACK
INPUT 3
INPUT 2
INPUT 1
GPIO GND
RED
PULLUP
VOLTAGE
LIGHT
GREEN
BROWN
GRAY
VIOLET
BLUE
BLACK
INPUT 3
INPUT 2
INPUT 1
GPIO GND
RED
PULLUP VOLTAGE
(not requied in this example)
LIGHT
GREEN
BROWN
GRAY
VIOLET
BLUE
BLACK
INPUT 3
INPUT 2
INPUT 1
GPIO GND
RED
PULLUP
VOLTAGE
+ve 12/24V
+ve 12/24V
-ve
V + V -
C
NO
LIGHT
GREEN
BROWN
GRAY
VIOLET
BLUE
BLACK
INPUT 3
INPUT 2
INPUT 1
GPIO GND
RED
PULLUP
VOLTAGE
+
Float switch
Warning light
or alarm
Bilge pump
Three way switch
manual on / off / auto on
INPUT/OUTPUT 2
INPUT/OUTPUT 1
INPUT/OUTPUT 2
INPUT/OUTPUT 1
INPUT/OUTPUT 2
INPUT/OUTPUT 1
INPUT/OUTPUT 2
INPUT/OUTPUT 1
INPUT/OUTPUT 2
INPUT/OUTPUT 1
INPUT/OUTPUT 2
INPUT/OUTPUT 1
GPIO sensor wiring - Bilge pump activation sensor
GPIO sensor configuration example
Note - A Pullup connection is not required in this example as it is driven high.
Sensor / control name Engine room bilge
Sensor / control type Bilge pump
Default input high Pullup disabled
Active when high Yes, normally closed

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vesper Cortex M1 and is the answer not in the manual?

Vesper Cortex M1 Specifications

General IconGeneral
BrandVesper
ModelCortex M1
CategorySwitch
LanguageEnglish