DGT / DGT60 / DGTQ / DGTP
15
• CLoCK DATE/TIME ADJUSTMENT (OPTIONAL) (§)
In this step one sets the date and time of the indicator; by pressing PRINT one is asked to enter, in this order, the
day, month, year, hour and minute.
The entry of each parameter must be confirmed with PRINT.
(§) the parameter is not displayed if there is no date/time option or if the rEPE functioning mode has been
selected, FmodE >> FunCt parameter.
NOTE:The date/time function is standard fitted in the DGTP version.
• tArE LOCKED / UNLOCKED / DISABLED TARE SELECTION(§)
LoCK locked tare
unLoCK unlocked tare
diSAb disabled tare
See the "TARE OPERATIONS" section for further functioning details, USER MAN. REF.
(!) LoCK
(§) The parameter is not displayed if one has selected the rEPE or MAStr functioning mode, FmodE >> FunCt
parameter.
•
AutoFF AUTO SWITCH-OFF
It is possible to enable the automatic switch off of the indicator (from 1 to 255 minutes), or disable it; the auto
switch-off starts working when, with unloaded scale, the weight has not been moved or a key has been pressed
during the set time: the display shows the blinking "- oFF – " message and an acoustic signal is emitted; then the
indicator turns off.
disAb auto switch-off disabled.
EnAb auto switch-off enabled (one will be asked to enter the number of minutes after which the indicator
must turn off: enter a number from 1 to 255).
(!) diSAb
(§) The parameter is not displayed if one has selected the rEPE functioning mode, FmodE >> FunCt parameter.
SEtuP SCALE CONFIGURATION
• ConFiG METRIC CONFIGURATION(§)
(§) The parameter is not displayed if one has selected the rEPE or MAStr functioning mode, FmodE >> FunCt
parameter.
(*) nChAn SELECTION OF NR. OF INDICATOR CHANNELS
1÷4 in SCALE WITH NON DEPENDENT CHANNELS functioning mode ("IND.CH." / "trAnSM")
2÷4 in SCALE WITH DEPENDENT CHANNELS functioning mode ("DEP.CH")
(!) Ch. 1
(*) With approved instrument the parameter is read-only.
ChAn SELECTION OF THE ACTIVE CHANNEL(§)
1÷4 in SCALE WITH NON DEPENDENT CHANNELS functioning mode ("IND.CH." / "trAnSM")
(§) The parameter is not displayed if one has set "dEP.CH" in the tYPE parameter or in case of a single
channel application, SEtuP >> ConFiG >> nChAn step.
FiLt..50
By pressing the PRINT key, one can enable/disable the 50 Hz filter By
no disables the 50 Hz filter