EnAb.tM ENABLING TIME
One enters the length of the output enabling in seconds (4 digits with a decimal). The output is disabled
once the set time has passed, starting from the moment of the activation (see following parameter). By
setting "000.0" the output remains always active.
Notes:
- The delay time is considered only if one has selected the "Set point on gross weight", "Set point o Net
weight" or "Set point on Pieces" as a output function.
- Once disabled, the output is only reenabled (before verifying again the enabling condition) if the disabling
condition takes place.
o dELAy ENABLING DELAY PERIOD
One enters the enabling delay period in seconds (4 digits with a decimal).
The output is enabled once the set time has passed, starting from the moment in which the condition takes
place. By setting "000.0" the output is enabled when the enabling condition takes place.
Notes:
- The output is enabled only if the enabling condition takes place for the length of time set.
- The delay is valid only for the enabling of the output. When the enabling condition no longer takes place
the output immediately is disabled.
- With switching condition upon stability, the output is enabled only when, after the set time has passed, the
weight shows to be stable.
- The delay time is considered only if one has selected the "Set point on gross weight", "Set point o Net
weight" or "Set point on Pieces" as a output function.
o SiGn SET POINT SIGN (§)
PoSit Functioning on positive weight.
nEGAt Functioning on negative weight.
(§) The parameter is displayed only if one has selected the "Set point on gross weight", "Set point o Net
weight" or "Set point on Pieces" as a output function.
The same configurations are valid for:
out.2 OUTPUT 2
out.3 (§) OUTPUT 3
out.4 (§) OUTPUT 4
out.5 (§) OUTPUT 5
out.6 (§) OUTPUT 6
(§) Optional output, with the DGTQ model.
• An.out ANALOGUE OUTPUT (DGT4 AN, DGTQ AN and DGTPAN)
o ChAn SELECTION OF THE ACTIVE CHANNEL(§)
1÷4 in SCALE WITH NON DEPENDENT CHANNELS functioning mode ("IND.CH." / "trAnSM")
(§) The parameter is not displayed if one has set "dEP.CH" in the tYPE parameter or in case of a single
channel application, SEtuP >> ConFiG >> nChAn step.
o ModE OPERATING MODE
Ao no = analogue output disabled.
Ao G = analogue output on the gross weight.
Ao n = analogue output on the net weight.
o AoMAX MAXIMUM VALUE
Setting of the maximum value of the analogue output.
o AoZEr SCALE ZERO VALUE
Setting of the analogue output value when the scale displays zero weight.