DGT / DGT60 / DGTQ / DGTP
60
bArC: PRINTING THE BAR CODE (ONLY CODE 39 TYPE)
no does not print the bar code.
yes.tot prints the bar code; in the totalizer functioning mode it is printed just in the single totalisation.
SuM prints the bar code; in the totalizer functioning mode it is printed just in the partial total.
both prints the bar code; in the totalizer functioning mode it is printed both in the totalisations as well as in
the partial total.
(!) no
NOTES:
- the weight values are expressed with 6 digits without decimal point and possibly with non significant zeros.
- between a weight value and the following one a space is inserted
- the bar code is printed as the last data, after the weight values, numeric codes and ticket number, but before the
time and date
THE FOLLOWING PARAMETERS ARE VISIBLE ONLY IF IN THE PREVIOUS STEP A PARAMETER DIFFERENT
FROM "no" HAS BEEN SET.
VdbArC: SELECTING THE VERTICAL DISTANCE OF THE BAR CODE FROM THE PREVIOUS TEXTS:
Enter a value with 3 digits, expressed in mm
(!) 5
LMbAr: SELECTING THE LEFT MARGIN
Enter a value with 2 digits, expressed in mm
(!) 15
hbAr: SELECTING BAR CODE HEIGHT
Enter a value with 2 digits, expressed in mm
(!) 10
bArFS: SELECTING THE PRINT FIELDS IN THE BAR CODE
Selectable fields: G; n; t; G n;G t; n G; n t; t G; t n; G n t; G t n; n G t; n t G; t G n; t n G.
(!) n
In which G is the gross weight, n is the net weight and t is the tare weight.
PntVb: PRINTING THE NUMERIC FIELD OF THE BAR CODE
no: the numeric field is not printed.
Si: the numeric field is printed under the bar code
(!) Si
PEEL: CONFIGURATION OF THE SENSOR WHICH PEELS OFF THE LABEL
on: sensor active
oFF: sensor not active
(!) oFF
GAP SETTING THE VERTICAL DISTANCE BETWEEN A LABEL AND THE FOLLOWING ONE
Enter the value in mm.
NOTE: if one uses a continuous form, set the value 00.
GROSS 1.000kg
TARE 0.000kg
NET 1.000kg
001000
001000
VdbArC
LMbAr
hbAr
VdbArC