EasyManua.ls Logo

Vetus M2.C5 - Page 45

Vetus M2.C5
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
43
5
Filling the cooling system
Remove the cap of the filler neck on the
top of the heat exchanger housing.
Remove the bolt from the upper side of the
thermostat cover, so that air can escape
from the cooling system.
Fill the cooling system.
Use a mixture of 40% antifreeze (ethylene-
glycol based) and 60% tap water or use a
special coolant.
For specifications see page 67.
The level of the coolant must be approx.
1 cm (3/8) below the lower edge of the
filler neck.
Bleeding will take place automatically dur-
ing filling!
Replace the filler cap.
After the engine has run for the first time
and has reached operating temperature
and has cooled down again to ambient
temperature, check the coolant level in the
heat exchanger housing.
If necessary, add coolant.
Maintenance
Coolant replacement
Every 1000 operating hours.
WATER HEATER
If a water heater is connected to the
engine and this heater is positioned
above the upper side of the engine
than bleeding of the heater will not take
place automatically! Fill the heater sep-
arately to bleed the cooling system
completely.
Never fill the cooling sys-
tem with sea water or
brackish water.
VD01005
;;yy
;y
;
;
y
y
;;
;;
yy
yy
;;yy
;;yy
;;;yyy
;
;
;
;
y
y
y
y
;y
;y
;;;;;
;;;;;
;;;;;
yyyyy
yyyyy
yyyyy
VD00158VD01004
COOLANT:2 CIL.: 2.2 litres (4 UKpt)
QUANTITIES :3 CIL.: 3.0 litres (5 UKpt)
(3/8)
340102.04 M2C5D506/M309 EN 14-04-2005 10:36 Pagina 43