18
3
WARNING
Never turn the key to the START posi-
tion while the engine is running.
Doing so will damage the starter motor.
Starting
Now turn the key further to the START
position.
Release the key as soon as the engine
fires (the key will return to the
ON posi-
tion) and throttle back.
Leave the key in this position while the
engine is running.
Check that the indicator lights for oil pres-
sure and alternator are off. Cooling water
should now flow out of the exhaust; if this
is not the case, stop the engine immedi-
ately. Before submitting the engine to full
load it should be brought up to operating
temperature as quickly as possible by run-
ning at 3/4 of maximum revs.
NEVER turn
the main switch off while the engine is run-
ning.
The instrument panel is provided with the
following instruments (Depending of the
type of panel, see page 10).
Use
Starting
WARNING
Release the key if the engine does not
fire within 10 seconds. Wait until the
starter motor has stopped running
completely before turning the key to
the
START position again. Never allow
the starter motor to run for more than
30 seconds consecutively.
VD00109
VD00110
340102.04 M2C5D506/M309 EN 14-04-2005 10:34 Pagina 18