48
6
Fuel system
Drain the water from the water
separator/fuel filter and the fuel tank.
Ensure that the tank is completely filled
with fuel.
Running with protective fuel mixture
Connect the fuel supply pipe to a can filled
with a mixture of one (1) part of engine oil*
to nine (9) parts of clean fuel**. Use this
mixture to run the engine at
no load for
approx. 10 minutes.
Stop the engine.
* Engine oil with protective properties.
E.g. Shell Super Diesel T 10W40
** Preferably water-free fuel.
Collect some fuel from the return pipe,
while engine is running.
Never run the engine under
load with this mixture of fuel
and oil.
Winter storage procedure
Winter lay-up
VD01006 VD00136