EasyManua.ls Logo

Vetus M2.D5 - Gearbox Oil Level Check

Vetus M2.D5
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30
5
Battery, battery connections
Keep battery clean and dry.
Remove battery cables (negative first).
Clean battery posts (+ and -) and clamps
and grease with acid-free and acid-resist-
ant grease.
Ensure that clamps make good contact
after reassembling. Hand tighten the bolts
only.
Checking specific gravity
Every Vetus Maintenance-free battery has
a hydrometer (1) built into the cover.
Visual inspection of the hydrometer will
show one of three conditions:
Hydrometer operation
Green dot visible - State of charge
65 % or more.
Dark - State of charge less than 65 %.
Recharge immediately.
Clear or light yellow - Electrolyte level
low.
In case of low level, caused by over-
charging the battery for a long period of
time with a voltage too high, replace
battery. Check alternator and/or voltage
regulator.
Maintenance
Battery, cables and connections
Every 100 operating hours.
VD00117 VD00118 VD00121 VD00122 VD00123
Vetus maintenance-free batteries
GREEN DOT ALL DARK CLEAR
340102.04 M2C5D506/M309 EN 14-04-2005 10:35 Pagina 30