27
5
VD00109
A second bleeding nipple is located at the
fuel injection pump.
Prime the fuel system by pumping the fuel
pump.
Close the bleeding nipples when all air
has escaped.
N.B. It is necessary to operate the lever
over the full stroke for proper operation.
Start the engine
Operate the starter switch until the engine
fires; release the starter switch if the
engine does not fire within 20 seconds.
Wait until the starter motor has stopped
before making a new attempt to start the
engine.
Repeat the above if the engine cuts out
after a short time.
Draining of water from the water separator/fuel filter
Every 100 operating hours.
Maintenance
VD01009VD01008
1410
340102.04 M2C5D506/M309 EN 14-04-2005 10:35 Pagina 27