55
7
Fault finding table
Troubleshooting
Possible fault
A Faulty or discharged battery.
B Loose or corroded connections
in starting circuit.
C Faulty starter-switch or faulty
starter-relay.
D Faulty starter-motor or pinion
does not engage.
E Starter relay is not engaged
due to a voltage too low; cau-
sed by a very long intermediate
cable from engine to control
panel.
Possible fault
A Fuel stop valve closed.
B (Nearly) Empty fuel tank.
C Air in fuel system.
D Fuel filter clogged with water
and/or contamination.
E Leaking fuel supply line or fuel
injection line.
F Faulty injector/injection pump.
G Vent line of fuel supply tank
clogged.
H Exhaust restricted.
1 Engine will not crank 2 Engine cranks but will not start, no smoke from exhaust
Remedy
A Check / recharge batte-
ry and check engine
alternator and/or battery
charger.
B Clean and tighten con-
nections.
C Check / replace.
D Check / replace starter-
motor.
E Install an auxiliary starter
relay.
Remedy
A Open.
B Refill.
C Check and bleed.
D Check or replace.
E Check / replace.
F Check, replace if requi-
red.
G Check / clean.
H Check.