59
7
Fault finding table
Troubleshooting
Possible fault
A Oil level too high.
B Excessive inclination of engine.
Possible fault
A Air in fuel system.
B Faulty injector/injection pump.
C Water in fuel system.
D Faulty glow plugs.
E Incorrect valve clearance.
F Incorrect injection timing.
G Wrong fuel quality or contami-
nated fuel.
H Vapour in exhaust gases con-
denses as a result of very low
ambient temperature.
10A Blue exhaust smoke (idling) 10C White exhaust smoke (at full load)
Remedy
A Lower level.
B Check / Adjust.
Remedy
A Check and bleed.
B Check, replace if requi-
red.
C Check water separator.
D Check / replace.
E Adjust.
F Check / adjust.
G Check fuel. Drain and
flush fuel tank. Replace
with new fuel.
H -
Possible fault
A Insufficient intake air.
B Faulty injector / injection pump.
C Engine overloaded, max. rpm
is not reached.
10B Black exhaust smoke (at load)
Remedy
A Check.
B Check / replace if requi-
red.
C Check sizes of propeller.
340102.04 M2C5D506/M309 EN 14-04-2005 10:37 Pagina 59