- 42 -
the temporary power-on password. After the input is
correct, the system will automatically Password before
activation. The key will not appear on this interface if
the validity period or the number of valid times has not
been exceeded.
4. If the validity period verification function is turned on,
the validity period of the fusion splicer will be displayed
on this interface. If the validity period verification
function is turned off, the validity period of the fusion
splicer will not be displayed on this interface.If the valid
times verification function is turned on, the remaining
usage times will be displayed on this interface. If the
valid times verification function is turned off, the
remaining usage times will not be displayed on this
interface.
Appendix 1 Warning Information
Warning
information
Reason
Countermeasures
Incorrect
placement of left
fiber(LFPC)
1 Left fiber is
cleaved too
short;
2 The part of
left fiber put
into V-groove
is broken;
3 Left fiber is
not put into
the center of
V-groove
4 Left
propulsion
motor is
1.In the case of 1 or
2,re-cleave left fiber
and make sure the
cleaved length is
Appropriate
2.In the case of 3,
replace left fiber
3.If the breakdown
do
not match 123,do
Calibrate
System, If the
problem remains,
please contact the

Related product manuals