- 43 -
incorrectly
connected
after sales service
department
Right fiber
placement is
incorrect(RFPC)
1Right fiber is
cleaved too
short;
2The part of
right fiber put into
V-groove is
broken;
3Right fiber is
not put into the
center of
V-groove
4.Right
propulsion motor
is incorrectly
connected
Solutions refer to
the above
Left and Right
fiber
placement are
incorrect(LRFPC)
The same as
above
above Solution
refer to the
above
Left fiber is
unqualified(LFNQ)
1. Left fiber
surface is
dusty;
2.Left fiber is
cleaved
poorly, such as
core defect,
cladding defect
or fiber
incompleteness
1. In the case of
1,use
alcohol to clean the
left fiber
2.In the case of
2,remake
fiber
Right fiber is
unqualified(LFNQ)
1. Right fiber
surface is
dusty;
2.Right fiber is
Solutions refer to
the
above

Related product manuals