7.INITIAL TESTING.
EMERGENCY SHUTDOWN.
Due to the risk of fire and other hazards during the engraving process, the
engraving machine includes a large, easy-to-reach emergency stop button
near the control panel. Press it to stop the laser tube immediately.
When your engraver arrives, its emergency stop has been pressed and
must be rotated to the right and bounce upwards for the laser to work.
Before using the machine for any other work, you should test if it is working
properly. Start the water cooling system, place a piece of laserable scrap
on the work bed, close the lid, and press PULSE to fire the laser. Press
the emergency stop button and observe if the laser stops immediately. If
the laser continues to fire, the emergency stop does not work and must be
replaced before using the engcher. Turn off the machine and contact
customer service.
LID CLOSURE (INTERLOCK).
Due to the risk of blindness, burns, and other injuries from direct exposure
to the invisible engraving beam, the device
also automatically shuts off the laser when the protective cover is raised
during operation.
After making sure that the emergency stop button is working properly, you
should also test that the cover closure is working properly before doing any
other work on the machine. Start the water cooling system, place a piece of
laserable scrap on the work bed, close the lid, and press PULSE to fire the
laser. Release the button. Be careful not to expose yourself to or be hit by
any possible reflected lasers, open the lid as little as possible and try to fire
the laser again.
Note:If the laser is emitted, the automatic shut-off does not work and must
be repaired before using the engraver. Turn off the machine and
contact customer service.