2. Move the laser head to the center of the table and place a cloth under
the lens mount so that the lens will not be damaged if it accidentally falls
off the mount.
3. Unscrew the lens mount and rotate it to the left.
4. Remove the pressurized air hose and laser rail connection.
5. After placing the lens on clean lens cleaning paper, carefully turn the
lens holder so that the lens and its O-ring fall onto the cleaning cloth and
remove the lens from the lens mount.
6. Check the o-ring and, if necessary, clean it with a cotton swab and
lens cleaning paper towel or cloth.
7. Blow air onto the surface of the lens to remove as much coarse dust
as possible.
8. Inspect the lens surface and clean the lens with lens cleaning solution
and lens paper or cloth if necessary.
9. Hold the edge of the lens assembly with a lens cleaning tissue and
use lens cleaning solution. Hold the lens at an angle and rinse both
surfaces to wash away the dirt.
10. Place the lenses on a clean lens cleaning tissue and apply some
lens cleaning solution to one side of the lens. Allow the liquid to take
effect for about a minute, then gently wipe with lens cleaning paper
dipped in lens cleaning solution. Dry this side of the lens with a dry tissue
clean/cloth.