4.11 Technical data
Dimensions (W/D/H)
Unit Value
Footprint (approx.) mm
in
580 x 380
22.8 x15.0
Housing fully closed
(approx.)
mm
in
580 x 600 x 700
22.8 x 23.6 x 27.6
Minimum required space for
operation (approx.)
mm
in
730x 820x 920
28.7x 32.2x36.2
Base system
Unit Value
Weight (approx.) kg
lbs
149
328
Axes
– Rotational axis A/ B
5
360°/ ± 35°
Overvoltage category
(IEC60664-1)
II
External compressed air supply
Unit Value
Min/ max. air pressure bar
psi
6/ 8
90/ 120
Recommended air pressure bar
psi
7
100
required for all machine func-
tions
Air consumption (approx.)
– Ionizer deactivated
– Ionizer activated
l/min
cfm
l/min
cfm
50/65(at 6/8bar)
1.8/2.3cfm (at 90/120psi)
105/110(at 7/8bar)
3.7/3.9(at 100/120psi)
Air purity (ISO 8573-1:2010) Solid particles: class 3
Water content: class 4
Residual oil content: class 3
External air extraction system
Unit Value
Minimum extraction capacity l/min
cfm
3,500 (at 220 hPa)
123.6 (at 3.2 psi)
Suction unit Designed for the commercial
use in the dental sector
Equipped with a filter of the
filter class M
Ambient conditions
Unit Value
Relative air moisture 80%, non-condensing
Ambient temperature for stor-
age/transport
°C
°F
-20 – 60
-4 – 140
Ambient temperature for
operation
°C
°F
10 – 35
50 – 95
Location type Indoor
Maximum height above
mean sea level
m
ft
2000
6561
Ambient air (IEC60664-1) Dust free, pollution degree 2
Spindle
Unit Value
Model SFR 400P (synchronous)
Maximum rotational speed rpm 80,000
Nominal power under
continuous operation (S1)
W 440
Unit Value
Nominal power under unin-
terrupted periodic operation
(S6)
W 600
Peak power (P
max
) W 800
Diameter collet chuck mm 3
Tool changer
Unit Value
Maximum tools in magazine 16
Maximum tool length mm 40
Standard blank holder
Unit Value
Min./ max. disc diameter mm 98.5/ 98.8
Maximum disc height mm 40
Min. / max. height of the disc
rim
mm 9.8/ 10.5
Maximum block dimensions
(L/D/H)
mm 45x 20x 20 (requires block
holder)
Cooling liquid system
Unit Value
Cooling liquid
– For titanium
Drinking water
Emulsion of water and the
cooling lubricant Tec Liquid
Pro
Maximum tank capacity l
qt
3.4
3.6
Blank changer
Unit Value
Number of slots 10
Mounting method Frame-less
Connections
Unit Value
Pneumatic connection, push-
in fitting (Diameter)
mm 8
Power connection VAC
Hz
W
100 – 240
50/60
750
Glass fuse T6,3A L250V
Network port
– Speed
RJ-45
10BASE/100BASE-
TX/1000BASE-T (Auto-
sensing)
Data port for supported
suction unit or switching unit
Yes
Hose connection for external
air extraction system
(Diameter)
mm 45
R5 – Machine overview
EN 15
Original Operating Instructions:R5