CODE PARAMETERS
Code par. menu Parameter Name Programming method Permission Default value
1: Master Master By panel and PC software Only Engineer 111111
2: Trade Trade By panel and PC software Only Engineer 000000
3: Admin Admin By panel and PC software Only Engineer 222222
4: Manage Trade Card / By panel and PC software Only Engineer /
MASTER
The master code must to between 3 to 6 digits and must also
be dierent from the admin, trade and user codes. Entering the
correct master code will switch the panel in to programming
mode with engineer permissions.
Modify routine
press “1” to enter into edit mode;
insert new code;
press
;
insert the same code to conrm;
press to save or to delete characters or exit edit mode
without saving.
TRADE
The trade code works within the trade time band and only when
TRD is shorted to 0V.
It must be between 3 to 6 digits and dierent to all other codes.
Entering the correct code when the above requirements are
met will open the door for the programmed time.
If the code is left blank the Clear button will open the door
during the active trade time.
Modify routine
press “2” to enter into edit mode;
insert new code;
press
;
insert the same code to conrm;
press to save or to delete characters or exit edit mode
without saving.
ADMIN
The admin code will switch the door panel in the programming
mode similar to the master code but with restricted permissions.
The code must to between 3 to 6 digits and dierent from all
other codes.
Modify routine
press “3” to enter into edit mode;
insert new code;
press
;
insert the same code to conrm;
press to save or to delete characters or exit edit mode
without saving.
MANAGING TRADE CARD
Add, edit or delete proximity cards which can be used for trade
purposes only during active timeband settings.
Add routine
press “4” to enter into edit mode;
press “3” to add and then present a card to the reader when
asked;
press
to exit edit mode.
Art.4212 Audio/video digital front panel Programming

Other manuals for Videx 4000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Videx 4000 Series and is the answer not in the manual?

Videx 4000 Series Specifications

General IconGeneral
Series4000 Series
CategoryIntercom System
MaterialStainless Steel
Operating Voltage12V DC
Housing MaterialStainless steel
CompatibilityCompatible with Videx audio and video internal units

Related product manuals