Vitodens 100-W, B1HE/B1KE Combi Installation/Service
General
System Configuration (parameters)
Note: Parameter values in bold are factory settings.
508.0 “UTC time zone”
Setting Explanations
2
–24 to +24
Setting of the UTC time zone in which the boiler is located.
The factory setting is UTC +1 h
Time difference adjustable from –12 h to +12 h in increments of 0.5 h
896.0 “Display correction for outside temperature”
Setting Explanations
0
-10 to + 10
Correction of measured outside temperature
Correction in the factory setting 0 K (0°F)
Correction adjustable from -10 to + 10 K in 1 K increments
(-18°F to +10°F in 1.8°F increments)
912.0 "Automatic summer/wintertime changeover"
Setting Explanations
No
Yes
0
1
Automatic changeover switched off
Automatic changeover switched on
912.1 “Earliest day of changeover from winter to summertime”
Setting Explanations
25
1 to 31
Changeover from 02:00 h to 03:00 h occurs on the Sunday after or on this set date.
Day of changeover adjustable from 1st to 31st of the month
912.2 “Month of changeover from winter to summertime”
Setting Explanations
3
1 to 12
Month of changeover: March
Month of changeover adjustable from January to December
912.3 “Earliest day of changeover from summer to wintertime”
Setting Explanations
25
1 to 31
Changeover from 03:00 h to 02:00 h occurs on the Sunday after or on this set date.
Day of changeover adjustable from 1st to 31st of the month
912.4 “Month of changeover from summer to wintertime”
Setting Explanations
10
1 to 12
Month of changeover: October
Month of changeover adjustable from January to December
1098.4 “Gas volume correction factor”
Setting Explanations
1,0000
.7000 to 1.0000
Value is provided on the gas supplier’s bill. Used for gas consumption data.
Calorific value adjustable from 0.7000 to 1.0000 in increments of 0.0001.