EasyManua.ls Logo

Viessmann B2HAH13 - User Manual

Viessmann B2HAH13
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Please file in Service Binder
5461 885 - 04 01/2019
Operating Instructions
VITODENS
r
200-W/222-F
With Vitotronic 200 HO1B Controls
Read and save these instructions
for future reference.
Product may not be exactly as shown
IMPORTANT
H
Do not store or use gasoline or other
ammable liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliances.
Do not touch any electrical switches,
do not use any phone in your building.
Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
If you cannot reach your gas supplier,
call the re department.
Installation and service must be
performed by a quali ed installer,
service agency or the gas supplier.
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
WARNING
Improper installation, adjustment, and/
or operation could cause carbon monoxide
poisoning resulting in injury or loss of life.
This product must be installed and serviced
by a professional service technician who is
experienced and qualified in hot water boiler
installation and gas combustion.
WARNING
Vitodens 200-W, B2HA and B2HB
Models 19 to 150, 68 to 530
Wall-mounted, gas-fired condensing boiler
For operation with natural gas and liquid propane gas
Heating input: 12 to 530 MBH
3.5 to 155 kW
Vitodens 222-F B2TA and B2TB
Models 19, 35, 68, 125
Floor-mounted, gas-fired condensing storage combi boiler
For operation with natural gas and liquid propane gas
Heating input: 12 to 125 MBH
3.5 to 37 kW

Table of Contents

Questions and Answers

  • M
    Marie LynnSep 13, 2025
    What does Fault Code C4 mean on my Viessmann Boiler?
    • S
      Stephen WilliamsSep 14, 2025
      If your Viessmann Boiler displays Fault Code C4, there is a communication error with the Open Therm extension. Check the Open Therm extension.
  • B
    Brittany HarrisSep 14, 2025
    What does Fault Code d6 mean on my Viessmann B2HAH13?
    • S
      Samantha JohnsonSep 14, 2025
      If your Viessmann Boiler displays Fault Code d6, input DE1 reports a fault at extension EA1. Remove fault at appliance concerned.
  • B
    Brittany RichardsonSep 14, 2025
    What does Fault Code d8 mean on my Viessmann Boiler?
    • E
      Elizabeth McguireSep 14, 2025
      If your Viessmann Boiler displays Fault Code d8, input DE3 reports a fault at extension EA1. Remove fault at appliance concerned.
  • A
    Andrew SmithSep 14, 2025
    What does Fault Code E4 mean on my Viessmann B2HAH13 Boiler?
    • J
      John TaylorSep 14, 2025
      If your Viessmann Boiler displays Fault Code E4, there is a fault with the supply voltage of 24V. Replace the control unit.
  • N
    Nicole VelasquezSep 14, 2025
    What to do if my Viessmann B2HAH13 shows error F4?
    • G
      Gabriel ReynoldsSep 15, 2025
      If your Viessmann Boiler displays the error code F4, it indicates no flame signal. To resolve this, check the ionisation electrode and connecting cable, measure the ionisation current, check the gas pressure, check the gas train, ignition, ignition module, ignition electrodes and the condensate drain. After these checks, press the reset button R.
  • D
    Dawn JordanSep 15, 2025
    What does error code F2 mean on my Viessmann Boiler and how to fix it?
    • L
      Lisa MaySep 15, 2025
      Error F2 on your Viessmann boiler indicates that the temperature limiter has responded. Address this by checking the heating system fill level, the circulation pump, and vent the system. Also, inspect the temperature limiter and connecting cables. Finally, press the reset button R.
  • M
    Mathew OwensSep 15, 2025
    How to fix error code F1 on a Viessmann B2HAH13?
    • W
      Whitney HinesSep 15, 2025
      Error code F1 indicates that the flue gas temperature limiter has responded. To fix this, check the heating system fill level, vent the system, and after the flue system has cooled down, press reset button R.
  • C
    Cheryl MataSep 15, 2025
    What should I do if my Viessmann Boiler displays error code Fd?
    • M
      Mark JacksonSep 15, 2025
      If your Viessmann Boiler shows error code Fd, it indicates a burner control unit fault. Check the ignition electrodes and connecting cables. Verify that there isn't a strong electromagnetic interference (EMC) field near the equipment. Press reset button R. If the fault persists, replace the control unit.
  • S
    Stephen MccartySep 15, 2025
    Why is my Viessmann B2HAH13 showing error code F3?
    • M
      Molly Evans DVMSep 16, 2025
      If your Viessmann Boiler is showing error code F3, it means a flame signal is already present at burner start. To resolve this, check the ionisation electrode and connecting cable, then press reset button R.
  • S
    Stephanie MorseSep 16, 2025
    How to troubleshoot error code E8 on a Viessmann Boiler?
    • K
      Kevin WuSep 16, 2025
      If your Viessmann boiler displays error code E8, it indicates that the ionisation current lies outside the permissible range. To troubleshoot this, check the ionisation electrode and cable, then press the reset button R.