EasyManua.ls Logo

Viessmann B2HAH13 - User Manual

Viessmann B2HAH13
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Please file in Service Binder
5461 885 - 04 01/2019
Operating Instructions
VITODENS
r
200-W/222-F
With Vitotronic 200 HO1B Controls
Read and save these instructions
for future reference.
Product may not be exactly as shown
IMPORTANT
H
Do not store or use gasoline or other
ammable liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliances.
Do not touch any electrical switches,
do not use any phone in your building.
Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
If you cannot reach your gas supplier,
call the re department.
Installation and service must be
performed by a quali ed installer,
service agency or the gas supplier.
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
WARNING
Improper installation, adjustment, and/
or operation could cause carbon monoxide
poisoning resulting in injury or loss of life.
This product must be installed and serviced
by a professional service technician who is
experienced and qualified in hot water boiler
installation and gas combustion.
WARNING
Vitodens 200-W, B2HA and B2HB
Models 19 to 150, 68 to 530
Wall-mounted, gas-fired condensing boiler
For operation with natural gas and liquid propane gas
Heating input: 12 to 530 MBH
3.5 to 155 kW
Vitodens 222-F B2TA and B2TB
Models 19, 35, 68, 125
Floor-mounted, gas-fired condensing storage combi boiler
For operation with natural gas and liquid propane gas
Heating input: 12 to 125 MBH
3.5 to 37 kW

Table of Contents

Questions and Answers

  • M
    Mrs. Ashley Rodriguez DVMSep 16, 2025
    What does error code F9 mean on my Viessmann B2HAH13 Boiler?
    • M
      Michael AdkinsSep 16, 2025
      If your Viessmann Boiler displays error code F9, it means the fan speed is too low during the burner start. To address this, check the fan, the fan connecting cables and power supply, and the fan control. Then, press the reset button R.
  • N
    natashacarterSep 16, 2025
    What to do if Viessmann B2HAH13 Boiler shows error code FA?
    • R
      rebeccawardSep 16, 2025
      If your Viessmann Boiler displays error code FA, it indicates that the fan is not at a standstill. To resolve this, check the fan, fan connecting cables, and fan control. Then, press reset button R.
  • S
    Steven ButlerSep 16, 2025
    How do I fix a Viessmann B2HAH13 Boiler displaying error code FC?
    • H
      hollandpaigeSep 16, 2025
      If your Viessmann Boiler displays error code FC, it indicates a gas train fault, faulty modulation valve control, or a blocked flue gas path. To resolve this, check the gas train and the flue gas system. Then, press reset button R.
  • D
    Deanna SchneiderSep 16, 2025
    What does error code FE mean on a Viessmann Boiler?
    • S
      Shane SimmonsSep 17, 2025
      If your Viessmann Boiler displays error code FE, it indicates that the boiler coding card or main PCB is faulty. To attempt a fix, press reset button R. If the fault persists, replace the boiler coding card or control unit.
  • H
    Hector AlvarezSep 17, 2025
    What causes error code E9 on a Viessmann B2HAH13?
    • Y
      Yesenia StephensonSep 17, 2025
      Error code E9 on a Viessmann Boiler indicates that the ionisation current lies outside the permissible range during calibration. To resolve this, check the ionisation electrode and cable, check the flue gas system for tightness, and press reset button R.
  • L
    Leslie AyersSep 18, 2025
    What does error code EA mean on my Viessmann Boiler?
    • J
      James DaySep 18, 2025
      If your Viessmann Boiler displays error code EA, it indicates that the ionisation current lies outside the permissible range during calibration. To resolve this, check the ionisation electrode and cable, and then press reset button R.
  • M
    Megan Booth MDSep 18, 2025
    What does error code EC mean on my Viessmann Boiler?
    • D
      Denise SawyerSep 18, 2025
      If your Viessmann Boiler displays error code EC, it indicates that the ionisation current lies outside the permissible range during calibration. To resolve this, check the ionisation electrode and cable, then press reset button R.
  • L
    Lauren SalazarSep 18, 2025
    Why does my Viessmann Boiler show error code Eb?
    • A
      Amber CisnerosSep 18, 2025
      If your Viessmann Boiler shows error code Eb, it indicates that heat draw-off is repeatedly too low during calibration. Initiate a heat draw-off. Switch the boiler OFF and ON again. Press reset button R. Set coding address 12:1. This special function leads to heat being transferred to the heating circuit during calibration.
  • C
    chanannaSep 18, 2025
    What should I do if my Viessmann B2HAH13 displays error code FF?
    • C
      Cindy TorresSep 18, 2025
      If your Viessmann Boiler displays error code FF, it indicates an internal fault or that the reset button R is blocked. Try starting the equipment again. If it will not restart, replace the control unit.
  • D
    Douglas WhiteSep 18, 2025
    What does error code F8 indicate on a Viessmann B2HAH13?
    • C
      Carlos SilvaSep 18, 2025
      If your Viessmann Boiler displays error code F8, it indicates that the gas valve closes too late. To resolve this, check the gas train and both control paths. Then, press reset button R.

Viessmann B2HAH13 Specifications

General IconGeneral
ModelB2HAH13
CategoryBoiler
Fuel TypeNatural Gas / Propane
Efficiency95%
AFUE95%
Warranty10 years
Gas Connection Size3/4 inch
Water Connection Size1 inch