15
In access point mode, open source licences can be
scanned and wireless router settings can be carried
out.
Enable access point mode, e.g. after replacing the
wireless router.
Activating access point mode
Press reset button A
and hold down for longer than
5 seconds, but no longer than 30 seconds: See chap-
ter "Display and controls".
LED
pulsates yellow:
Access point mode is active.
Deactivating access point mode
1. Access point mode is deactivated automatically
after 5 minutes.
Or
2.
Press reset button
A
again and hold down for lon-
ger than 5 seconds, but no longer than 30 sec-
onds: See chapter "Display and controls".
LED is no longer illuminated.
Access point mode is deactivated.
Note
During commissioning, access point mode is enabled
automatically as soon as you plug in the plug-in power
supply unit. Access point mode remains active until
Vitoconnect commissioning is complete. Manual disa-
bling of access point mode is not required.