VITODENS 100-W
Installation and Service
Instructions
for use by heating contractor
Vitodens 100-W
WB1A Series
Wall-mounted, natural gas-fired condensing boiler
For natural gas
Heating input 29 to 100 MBH
8.5 to 29.3 kW
Read and save these instructions
for future reference.
IMPORTANT
Vitodens 100-W, WB1A
(with preinstalled coaxial vent pipe
adaptor)
Please file in Service Binder
5581 775 v1.3 08/2009

Questions and Answers

  • A
    Adrian JohnsonAug 30, 2025
    What does fault code 18 mean on my Viessmann WB1A007 Boiler?
    • K
      Kendra JonesAug 30, 2025
      If your Viessmann Boiler displays fault code 18, it indicates a lead break in the outside temperature sensor. Check the outside temperature sensor and lead.
  • G
    Gregory HallSep 7, 2025
    What does Fault code 30 mean on a Viessmann WB1A007 Boiler?
    • J
      John FreemanSep 7, 2025
      If your Viessmann Boiler displays Fault code 30, this indicates a short circuit in the boiler water temperature sensor. You should check the boiler water temperature sensor.
  • M
    Megan AyalaAug 29, 2025
    What does fault code 10 mean on my Viessmann Boiler?
    • A
      andersenshannonAug 29, 2025
      If your Viessmann Boiler displays fault code 10, it indicates a short circuit in the outside temperature sensor. Check the outside temperature sensor and lead.
  • W
    Wayne HatfieldSep 18, 2025
    What to do if Viessmann WB1A007 shows fault F4 and gas train opens?
    • A
      Adrian WhiteSep 18, 2025
      If your Viessmann Boiler displays fault code F4 and the gas train opens, check the gas train's control voltage (230 V) and the gas supply pressure.
  • C
    Curtis RobertsonSep 8, 2025
    What does Fault code 10 mean on a Viessmann WB1A007 Boiler?
    • R
      Richard CarterSep 8, 2025
      If your Viessmann Boiler shows Fault code 10, it means there is a short circuit in the outside temperature sensor. Check the outside temperature sensor and its lead.
  • J
    Joshua SanchezSep 12, 2025
    What to do if the fan in my Viessmann WB1A007 starts no after approx. 51 s?
    • D
      Diana KaufmanSep 12, 2025
      If the fan in your Viessmann Boiler does not start after approximately 51 seconds, check the following: 1. The fan itself. 2. The fan connecting cables. 3. Power at the fan. 4. Fan control.
  • S
    Samantha MitchellSep 16, 2025
    What to do if Viessmann WB1A007 burner shuts down below set temperature?
    • D
      Dr. Jessica GallowaySep 16, 2025
      If your Viessmann Boiler burner shuts down below the set boiler water temperature and restarts immediately, check the flue system for tightness to prevent flue gas recirculation. Also, inspect the condensate drain and verify the gas flow pressure.
  • E
    Elizabeth WatersSep 23, 2025
    What to do if Viessmann WB1A007 displays fault F4?
    • E
      Erica BarnettSep 23, 2025
      If your Viessmann Boiler is showing fault F4, check the ionisation current, the electrode adjustment, the condensate drain, and the gas line for airlocks.
  • B
    Bradley PayneAug 26, 2025
    What to do if my Viessmann WB1A007 shows displayed fault code 52?
    • M
      Maria ScottAug 26, 2025
      If your Viessmann Boiler is showing fault code 52, check the connections and lead to the flow sensor. If necessary, replace the sensor.
  • K
    kristarossAug 25, 2025
    What to do if my Viessmann WB1A007 Boiler shows fault F4?
    • T
      Timothy PatelAug 26, 2025
      If your Viessmann Boiler displays fault code F4, there are several potential solutions: * Check the ignition module connection. * Check the gas train (control voltage 230 V) and the gas supply pressure. * Check the ionisation current, the electrode adjustment, and the gas line for air-locks.

Viessmann WB1A007 Specifications

General IconGeneral
BrandViessmann
ModelWB1A007
CategoryBoiler
LanguageEnglish

Related product manuals