VITODENS 100-W
Installation and Service
Instructions
for use by heating contractor
Vitodens 100-W
WB1A Series
Wall-mounted, natural gas-fired condensing boiler
For natural gas
Heating input 29 to 100 MBH
8.5 to 29.3 kW
Read and save these instructions
for future reference.
IMPORTANT
Vitodens 100-W, WB1A
(with preinstalled coaxial vent pipe
adaptor)
Please file in Service Binder
5581 775 v1.3 08/2009

Questions and Answers

  • H
    Hunter RichardsSep 1, 2025
    What to do if Viessmann Boiler displays fault F2?
    • R
      reneeolsenSep 1, 2025
      If your Viessmann Boiler is showing fault code F2, indicating that the temperature limiter has responded, you should check the heating system fill level and the circulation pump. Make sure to vent the system. Inspect the temperature limiter and its connecting leads. Finally, press the "Reset" button.
  • M
    Martha NicholsSep 1, 2025
    What to do if Viessmann WB1A007 shows fault E3?
    • D
      Debra LloydSep 1, 2025
      If your Viessmann Boiler displays fault E3, indicating a fault in the safety chain, you should check the temperature limiter and its connecting leads. Also, check the control unit; replace it if necessary.
  • M
    Melanie WilliamsSep 2, 2025
    How to fix Viessmann WB1A007 fault F9?
    • R
      robinhawkinsSep 2, 2025
      If your Viessmann Boiler displays fault F9, and the cause is fan speed being too low during burner start, examine the fan, its connecting cables, and the power supply. Check the fan control. Then, press the "Reset" button.
  • L
    Leonard YuSep 2, 2025
    What to do if Viessmann WB1A007 Boiler shows fault F4 (Check gas train)?
    • K
      Kevin RussellSep 3, 2025
      If your Viessmann Boiler displays fault F4 related to the gas train, you should check the gas train, ensuring the control voltage is at 230V. Also, verify the gas supply pressure.
  • M
    Melanie RoweSep 3, 2025
    What to do if Viessmann WB1A007 Boiler shows fault F4 (Measure ionisation current)?
    • J
      Jessica HodgesSep 3, 2025
      If you're seeing fault F4 on your Viessmann Boiler related to measuring ionization current, you should measure the ionization current. Also, check the electrode adjustment and inspect the gas line for any airlocks.
  • R
    Roger StoneSep 4, 2025
    What to do if Viessmann WB1A007 Boiler shows fault F9 after approx. 51 s?
    • N
      Nicole MannSep 4, 2025
      If your Viessmann Boiler displays fault F9 after approximately 51 seconds, check the fan, fan connecting cables, power to the fan, and fan control.
  • J
    Jennifer CoffeySep 4, 2025
    How to solve the issue when Viessmann WB1A007 control unit issues no Increase set value?
    • B
      Brian PaceSep 4, 2025
      To address the issue where the Viessmann Boiler control unit does not increase the set value, increase the set value and ensure that heat is being drawn off.
  • M
    michael43Sep 5, 2025
    What to do if Viessmann Boiler shows Fault F4 (Check the ionisation current)?
    • A
      Amanda SmithSep 5, 2025
      If your Viessmann Boiler shows Fault F4 related to the ionization current, you should check the ionization current itself. Also, inspect the electrode adjustment and the gas pipe, ensuring there are no air-locks.
  • W
    Walter PerezSep 5, 2025
    What to do if Viessmann WB1A007 Boiler shows Fault F4 (Check the gas train)?
    • M
      Megan SimpsonSep 5, 2025
      If your Viessmann Boiler displays a Fault F4 related to the gas train, examine the gas train, ensuring the control voltage is at 230 V. Also, verify the gas supply pressure.
  • M
    Mr. Eddie ReeseSep 6, 2025
    What to do if Viessmann WB1A007 Boiler stops below the set boiler water temperature and restarts immediately?
    • T
      Tracy VincentSep 6, 2025
      If your Viessmann Boiler stops below the set boiler water temperature and restarts immediately, you should check the flue gas system for tightness, looking for flue gas recirculation. You should also check the gas flow pressure.