32
c) 3 PSI drop takes 30 seconds or less to generate:
Automatic inflation, turns on intermittently and two beeps
every 5 seconds.
d) 3 PSI drop takes 2 seconds or less to generate:
Automatic inflation, turns on permanently and three beeps
every 2 seconds.
Note: It there are air leaks in two or more circuits, only those circuit pressures will be displayed and in
sequential order.
In Manual Mode when an air leak is detected the system automatically turns to Sequential Mode and
displays the circuit/s being pressurized.
4 – Excessive Loss of Pressure
If the air leak is too big and the vehicle’s air compressor cannot compensate for it, the system will turn off
automatically and will display the air tank pressure (P) warning the driver with 3 beeps every 2 seconds.
Factory setting for the air tank pressure (P) warning is 80 PSI – 5.5 BAR.
5 – Alarm OFF
Press to turn the alarm off. If turning the alarm off when the system is inflating one or more circuits,
the alarm will automatically reconnect after 20 minutes.
6 – Circuit Deactivation
To temporarily deactivate a circuit proceed as follows:
a) Turn display to Manual Mode pressing or for 3 seconds.
b) Select the circuit to deactivate using or .
c) Press to confirm. A beep and the circuit number blinking is confirmation that the circuit has been
deactivated.
To cancel deactivation turn contact key off and on.
7 – Dimming Display
To decrease/increase display luminosity keep pressed the key until desired level.
.
.