EasyManua.ls Logo

Viking 30'' W - Electrical Requirements: Built-In Electric 30 Wall Ovens; Electrical Specifications and Wiring; Electrical Connection Options and Grounding

Viking 30'' W
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
BUILT-IN ELECTRIC 30" WALL
ELECTRICAL REQUIREMENTS
Description 30" Wide Single Oven 30" Wide Double Oven
Electrical Requirements 4-wire with ground, 240-208/120 VAC/60 Hz, 40 amp electrical
connection. Unit is equipped with No. 10 ground wire in conduit.
Should be fused separately.
Maximum Amp Usage 240V - 18.9 amps 240V - 31.8 amps
208V - 14.2 amps 208V - 23.9 amps
Broil Rating 240V 208V
Maxi Broil 8 pass 3000 watts 2250 watts
Mini Broil 4 pass 1250 watts 940 watts
Baking Rating 240V - 2935 watts 208V - 2205 watts
Convection Cook Rating 240V - 2200 watts 208V - 1650 watt
ELECTRICAL CONNECTIONS
1. With the oven positioned in front of the cabinet opening, connect the wire leads extending from the
conduit to the junction box, making sure the neutral (white) wire is connected to the appropriate
terminal Check your local code to see which of the following options below should be used in
grounding the unit.
OPTION 1: Connect the neutral (white) wire and the grounding (green) wire with the incoming
neutral (white) power supply line.
OPTION 2: If the junction box is grounded, untwist the grounding (green) wire and attach to the
junction box. Attach the neutral (white) wire to the neutral (white) power supply line.
OPTION 3: Untwist the grounding (green) wire and attach it to a suitable ground. Attach neutral
(white) wire to the incoming neutral (white) power supply line.
DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE. SUCH USE MAY RESULT IN A FIRE,
ELECTRICAL SHOCK OR OTHER PERSONAL INJURY.