COMPONENTS ( Con’t)
RELAY #2 - #3 - #5 (PM010025)
VDSC305-VDSC365-VESC305-VDSC485(RH)
Function: Setting the selector switch to clean closes
the Heating Element circuits 4-F, 1-N, 2-L2, 3-L2
and Door Lock Module / Timer circuit J-6, energizing
Relay #2.The thermostat cycling contacts 1 to 2 and
the clean switch contacts 3 to 4 close energizing
Relay #3. Relay #3 allows circuit J-6 to turn on the
Clean Indicator Light and enable the Door Lock
Module / Timer to close Relays LS1-L1 and LS2 -
M1. This powers the Door Lock Motor until 10
seconds after Sensor 3 is signaled by VC that Door
Lock Switch SW2 has been closed mechanically
(along with SW3) by the Door Lock Bolt.
RELAY #4 (PM010025)
VDSC485(LH) --CVDSC305/365