19
VOLTAGE READINGS
MEASURED WITH DOOR OPEN
T4 107VAC 70VAC
T3 4VAC 16VAC
T2 4VAC 16VAC
T1 5VAC 1VAC
MEASURED WITH DOOR LOCKED
T4 80VAC 56VAC
T3 85VAC 56VAC
T2 90VAC 56VAC
T1 93VAC 56VAC
VC--4VDC
SENSOR 3--3VDC SW2 closed in self clean
(Locked).
SENSOR 4--4VDC SW1 closed with clean
lock open.
M1--120VAC lock motor supply voltage.
(31VAC in locked position)
LS2--70VAC (unlocked)--55VAC (locked)
L1-- 70VAC (unlocked)--56VAC (locked)
L2/M2--16VAC(unlocked)--32VAC (locked)
LS1--107VAC (locked or unlocked)
SEL--120VAC SUPPLY