20
Diagnostics
Service Tests (continued)
143 Machine Compartment Thermistor
This test will check the machine compartment temperature. You will see the actual temperature, OP open
thermistor, or SH shorted thermistor.
151 Fresh Food Door State
This test will check the fresh food door switch(es). When either door is open, the display should read OP
(open) and when both doors are closed, the display should read CL (closed).
Note: By pushing either fresh food door switches, you can toggle state from OP (open) to CL (closed).
152 Freezer Food Door State
This test will check the freezer door switches. When the door is open, the display should read OP (open) and
when the door is closed, the display should read CL (closed).
Note: By pushing freezer door switch, you can toggle state from OP (open) to CL (closed).
174 Water Actuator Internal Dispenser
Display shows the state of the internal dispenser (ON or OFF).
143 72
Press either button to toggle
through test cycles
Actual machine compartment
temperature
151 CL
Press either button to toggle
through test cycles
152 CL
Press either button to toggle
through test cycles
174 OFF
Press either button to toggle
through test cycles
Press either button to cycle
Internal Dispenser ON or OFF