8. INTRUSION DETECTION ALARM SYSTEM.
The menu that manages the alarm system is called the SAI control panel and is active only if the By-me intru-
sion detection alarm system is also installed.
The system is managed according to "zones" and "partitions"; the zones are associated with the alarm sensors
(for example bedroom IR sensor, kitchen window contact, etc.) while a group of zones is called a "partition" (for
example all the contacts of the day zone, etc.).
The alarms displayed/signalled can be of different types:
- Intrusion alarm (intruders in the active zones of the system).
- Tamper alarm (tampering damaging the system devices).
- Technical alarm (for example water sensor, gas sensor, etc.). This is a type of alarm that does not activate the
sirens but generates the signals via GSM (if there is the communicator), it closes the solenoid valves, etc.
- No mains (with no mains power the battery powered back-up unit triggers to power the system).
Main menu
Alarm System
The control panel's main screen (Fig. 19) displays the icons relating to the options most frequently used.
•
: deactivates signalling the current alarm. This option is used to silence the sirens (if there is an alarm) or
to reset a previous alarm.
Notice: Stop Alarm silences the sirens but does not deactivate the system.
•
: deactivates the system (when the system is deactivated the displayed icon is ON that, if selected, acti-
vates the intrusion detection alarm system);
•
: used to obtain a quick partitioning that will involve all the connectors (done by any user or connector).
This function is useful, for example, when you want to move about freely in a zone of the house even if the parti-
tioning of which it is a part is active or to be able to leave a window open even if it is included in a zone to activate.