INSTRUCTION FOR USE ENGLISH
9
WORKING MODE DESCRIPTION
HOW TO OPERATE
DISPLAY DESCRIPTION
Normal mode
- Key (53) on
- One button start (51) on
- Seat safety switch (2) on
1. Hour meter point does not flash.
2. The brush arrow does not rotate.
3. The fan does not flash.
4. The tap water does not flash.
5. The actuator puts down to the first level
brush pressure.
- Key (53) on
- One button start (51) on
- Seat safety switch (2) on
- Accelerator pedal (32)
pressed
1. Hour meter point flashes.
2. The brush arrow rotates.
3. The fan flashes. (Four blades)
4. The tap water flashes.
Silent mode
- Key (53) on
- One button start (51) on
- Seat safety switch (2) on
1. Hour meter point does not flash.
2. The brush arrow does not rotate.
3. The fan does not flash.
4. The tap water does not flash.
- Key (53) on
- One button start (51) on
- Press vacuum system ad-
justment button (54) on for 1
second
- Seat safety switch (2) on
- Accelerator pedal (32)
pressed
1.Hour meter point flashes.
2.The brush arrow rotates.
3.The fan flashes. (Three blades)
4.The tap water flashes.
Off mode
- Seat safety switch (2) off
- One button start (51) off
- Key (53) on
1. Hour meter point does not flash.
2. All panel button closure.
(The vacuum motor delays 12 seconds to
stop.)
3. The brush head puts up to the highest posi-
tion.
4. “STOP” sign will alternate with the screen.
- Key (53) off
- Or emergency button (29)
on, there will no display
1.The power cut off.
2.The display is off.
Note: After turning off the one button start
(51), wait until the brush head raises to the
full up position, before turning off the key
(53).