Testing the system
48 D-307084 PowerMaster-360R User's Guide
To display the temperature or light intensity of zones on the control panel,
press .
6
The panel reads the temperature and light intensity of each zone. The
display alternates between the temperature, the light intensity, the sensor
number and the sensor location.
7
Repeatedly click the button to review the temperature and light
intensity of each zone.
When the temperature of all zones has been reviewed, the display reads
[DEVICE TESTS END]. Press the or the button to confirm
the test and then move to the next step to test the other devices.
D. To test all other devices
The display now reads [TEST ALL DEVICES].
To enter the devices test procedure, press .
The display reads [NOT ACTIVE NNN]. NNN indicates the number of enrolled
devices in the panel that have not been tested yet. This number automatically
drops one count for every tested device. To initiate devices test, press .
The display shows the 1
st
device in the list of untested devices. The display
alternates between the device number, the device type (e.g. magnetic
contact, keyfob, keypad, etc.), and the device location.
The test is performed by activating each device as explained in point 8 in
the Additional information table below.
Click to scroll through the list of all untested devices.
9
When all devices have been activated, the display reads [DEVICE TESTS
END] followed by [READY 00:00].
Press the or the button to confirm the test and then move to
the next step to test the email.
The display now reads [E-MAIL TEST].
10
To enter the email test procedure, press .
Check the private email inbox to view the sent email.
Additional information (Periodic Test)
Display shown in disarm state when all zones are secured (00:00 or other digits show present time).
If you have not already changed your personal code number, use the default setting – 1111.
If the INSTALLER CODE is used to enter the Periodic Test instead of the USER CODE, the device’s LED