EasyManua.ls Logo

Visonic PowerMaster-360R - 2. Operating the PowerMaster-360 R System; Preparing to Arm; Arming AWAY or HOME; Disarming and Preventing Alarm

Visonic PowerMaster-360R
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical appliance control
D-307084 PowerMaster-360R User's Guide 7
2. Operating the PowerMaster-360R system
For more information regarding terms used in this chapter, refer to Appendix C. G.
Basic arming and disarming
Following are a set of procedures for performing basic arming and disarming of the alarm system.
Preparing to arm
Before arming, make sure that READY is displayed.
READY HH:MM
This indicates that all zones are secured and you may arm the system as
required.
If at least one zone is open (disturbed) the display will show NOT READY.
NOT READY HH:MM
This indicates that the system is not ready for arming and in most cases that one or
more zones are not secured. However, it can also mean that an unresolved
condition exists such as certain trouble conditions, jamming etc., depending on
system configuration.
To review the open zones click . The details and location of the first open zone detector, usually an open
door or window sensor is displayed. To fix the open zone, locate the sensor and secure it that is close the door or
window. See "device locator" below for details on how to find the sensor. Each click of displays another
open zone or trouble indication. It is highly recommended to fix the open zone or zones, in order to restore the
system to the state of “ready to arm”. If you do not know how to do this, consult your installer.
Note: To quit at any stage and to revert to the "READY" display, click .
Device Locator: The PowerMaster-360R system has a powerful device locator that helps you to identify open
or troubled devices indicated on the screen display. While the screen displays an open or faulty device, the LED
on the respective device flashes indicating "it's me". The "it's me" indication will appear on the device within
max. 16 seconds and will last for as long as the screen displays the device.
Arming ‘AWAY' or HOME'
If the system is READY and/or Forced Arming is enabled proceed as shown below. For more information on
Forced Arming, see "Forced Arming AWAY or HOME" below.
If the system is NOT READY and Forced Arming is not permitted, review any open zone detectors to locate and
secure them.
If you want to arm using partitions, see "Partition Selection Process" and then proceed as shown below.
If the user has changed the state of the system from a high security mode to a lower security mode i.e. from ARM
to DISARM, or from ARM to HOME, he will be prompted to enter the user code thus bypassing the QUICK ARM
option.
PRESS
RESULTING DISPLAY
/
ARMING AWAY/HOME
If Quick Arm is disabled
ENTER CODE _ _ _ _
PLEASE EXIT NOW
Vacate the premises (ARM AWAY) OR
Move to interior zone (ARM HOME)
(Exit delay)
AWAY/HOME
ARM indicator lights steadily during the armed state.
Disarming and preventing the alarm
After entering the protected premises when an entry delay zone is operational, the panel sounds the entry delay
beeps. This sound alerts you to disarm the system before the end of the entry delay period.

Table of Contents

Other manuals for Visonic PowerMaster-360R

Related product manuals