Electrical appliance control
8 D-307084 PowerMaster-360R User's Guide
After disarming, different displays may appear indicating that the system is in a state of alarm MEMORY. The
MEMORY message disappears only when the system is rearmed. To disarm the system, proceed as shown:
PRESS
RESULTING DISPLAY
ENTER CODE _ _ _ _
[Enter Code] /
[Present tag]
Code / Present tag
READY HH:MM
ARM indicator extinguishes during the disarmed state. Disarming the system also stops the siren alarm,
irrespective of whether the alarm was initiated during the armed or the disarmed state.
Disarming under duress
If you are forcibly compelled to disarm the system, enter the duress code. The default value is 2580 or
alternative code set by the installer. Disarming take place normally but a silent alarm is transmitted to the
monitoring station.
Partition selection process
Access to any required partition is achieved through the use of an individual code or proximity tag. It is not
possible to access the INSTALLER MODE menu if one or more partitions are in the AWAY or HOME modes.
Before attempting to perform any operation on any given partition, you must select the required partition using
the individual code or proximity tag. Complete the following steps to select a partition:
PRESS
RESULTING DISPLAY
SELECT PARTITION
Enter partition # (1 - 3)
PARTITION 1
Note: The “Failure Tune” is heard when selecting a partition to which no sensors or peripherals were enrolled.
Special arming & disarming options
In addition to basic arming, PowerMaster-360R provides you with several advanced arming and disarming
options:
Switching from ‘HOME’ to ‘AWAY’
You do not have to disarm the system - just press
. The response is the same as in ARMING AWAY.
Vacate the premises before the exit delay expires.
Switching from ‘AWAY’ to ‘HOME’
You do not have to disarm the system - just press
.
Since this operation reduces the security level,
PowerMaster-360R prompts you to key in your master user code or user code, to ensure that you are an authorized
user.
PRESS
RESULTING DISPLAY
ENTER CODE _ _ _ _
[Enter code] /
[Present tag]
Code / Present tag
ARMING HOME
Move to interior zone
(Exit delay)
ARM HOME HH:MM
ARM indicator flashes during the armed state.