Testing the system
50 D-307084 PowerMaster-360R User's Guide
4 in the Additional information table below.
After a device has been activated, the control panel reads [Zxx IS ACTIVATED]
and the "N" indicator drops one count.
After all devices have been tested, the control panel reads [DEVICE TESTS END].
9.
Press .
5
Return to step 3
Additional information (Periodic Test per Partition)
1
Partitioning must be enabled by your installer.
2
If you have not already changed your personal code number, use the default setting 1111.
3
To cancel, press the button; the display reads [<OK> TO END]. Press the button.
4
To activate system devices during the "Periodic Test Per Partition"; make sure the device LED lights when
activated:
Contact sensor:
Open or close the door or window protected by the contact.
Motion sensors:
Perform a "walk test" of the detector as explained in the detector's datasheet.
Smoke sensors:
Perform a "Diagnostic test" as explained in the detector's datasheet.
5
Periodic test per partition will be interrupted (the panel returns to selected partition display) upon occurrence of
one of the following: 1) Disarm event by keyfob, keypad or pendant assigned to a selected partition; 2) PANIC,
FIRE or EMERGENCY event.