14 DE5467IP
NEXT
NEXT
READY 00:00
USER SETTINGS
NORMAL MODE
NEXT
ENTER CODE
1. NEW INSTL CODE
NEXT
2. ENROLLING
NEXT
3. DEFINE ZONES
NEXT
NEXT
5. DEFINE COMM
NEXT
[installer code]
OK
OK
INSTALLER MODE
NEXT NEXT NEXT
NEXT
05: ABORT TIME
OK
NEXT
09: EXIT MODE
OK
NEXT
13: SWINGER STOP
OK
NEXT
17: AUX BUTTON
OK
NEXT
status
instant
01: ENTRY DELAY 1
OK OK
02: ENTRY DELAY 2
OK
03: EXIT DELAY 04: BELL TIME
OK
OK
06: ALARM CANCEL
NEXT
OK
07: QUICK ARM
NEXT
quick arm ON
quick arm OFF
08: BYPASS
OK
NEXT
manual bypass
no bypass
force arm
OK
10: PIEZO BEEPS
NEXT
OK
11: TROUBLE BEEPS
NEXT
12: PANIC ALARM
OK
NEXT
OK
cross zone ON
cross zone OFF
14: CROSS ZONING
NEXT
OK
15: SUPERVISION
NEXT
superv time 1 h
superv time 2 h
superv time 4 h
superv time 8 h
16: NOT READY
OK
NEXT
normal
in supervision
OK
18: JAM DETECT
NEXT
4. DEFINE PANEL
entry dly2 00 s
entry dly2 15 s
entry dly2 30 s
entry dly2 45 s
entry dly2 60 s
entry dly2 3 m
entry dly2 4 m
exit delay 30 s
exit delay 60 s
exit delay 90 s
exit delay 120 s
exit delay 3 m
exit delay 4 m
bell time 1 m
bell time 4 m
bell time 8 m
bell time 10 m
bell time 15 m
bell time 20 m
cancel time 1 m
cancel time 5 m
cancel time 15 m
cancel time 60 m
cancel time 4 h
cancel inactive
enable beeps
off when home
disable beeps
enable beeps
off at night
disable beeps
silent panic
audible panic
disable panic
shut after 1
shut after 2
shut after 3
no shutdown
superv time 12 h
disable
PGM / X-10
UL (20/20)
EN (30/60)
class 6 (30/60)
disabled
NEXT
NEXT
NEXT
NEXT
entry dly1 00 s
entry dly1 15 s
entry dly1 30 s
entry dly1 45 s
entry dly1 60 s
entry dly1 3 m
entry dly1 4 m
abort time 00 s
abort time 15 s
abort time 30 s
abort time 45 s
abort time 60 s
abort time 2 m
abort time 3 m
restart exit
off by door
normal
NEXT
OK OK OKOK
OK
OK OK
OK
OK OK OKOK
OK
OK
OK
OK
OK
OK
OK
bell time 3 m
NEXT NEXT
abort time 4 m
NEXT
OK
NEXT
Note: The currently saved
options are displayed with
dark box at the right side of
the display. To review the
options, repeatedly click
NEXT or BACK until the
desired option is displayed,
then click OK (a dark box
will be displayed at the right
side).
Note: Force arm is not
applicable to the UK.
6. DEFINE GSM
NEXT
OK
19:LATCHKEY
latchkey on
latchkey off
OK
OK
20: NOT ACTIVE
no act time 3 h
no act time 6 h
no act time 12 h
no act time 24 h
no act time 48 h
no act time 72 h
no act disable
NEXTNEXT
NEXT
NEXT
OK
21: BACK LIGHT
OK
always on
off after 10 s
OK
22: DURESS
OK
duress code 2580
(Change the code or
enter 0000 to disable
duress function)
OK
Note: Duress code is not
applicable to the UK.
OK
23: PIEZO SIREN
piezo siren on
piezo siren off
OK
24: RESET OPTION
user reset
enginner reset
OK
OK
25: TAMPER OPTION
zone tamper on
zone tamper off
OK
OK
26: SIREN ON LINE
OK
enable on fail
disable on fail
OK
OK
27:MEMORY PROMPT
enable
disable
28: DISARM OPTION
any time
on entry all
OK
OK
on entry wirless
29 BELL/REP. OPT
EN standard
other
OK
OK
30: LOW-BAT ACK
keyfob L-B on
keyfob L-B off
OK
OK
31: SCREEN SAVER
scrn saver OFF
refresh by code
OK
refresh by key
32: CONFIRM TIME
disable
30 minutes
OK
OK
45 minutes
60 minutes
90 minutes
NEXT
35: USER PERMIT
Disable
OK
OK
entry + away kp
33: AC FAIL REP
5 minutes
30 minutes
OK
OK
60 minutes
180 minutes
NEXT
Enable
in
USA
Not applicable
in the USA
in
USA
in
USA
in
USA
Not applicable
in the USA
in
UK
in
UK
8. DEFINE OUTPUTS
NEXT
9. RECORD SPEECH
NEXT
10. DIAGNOSTICS
NEXT
11. USER SETTINGS
NEXT
12. FACTORY DEFLT
NEXT
13. SERIAL NUMBER
<OK> TO EXIT
NEXT
NEXT
14. START UL/DL
NEXT
NEXT
7. DEFINE PWRLNK