Troubleshooting
Problem Possible Causes Solutions
After
installation, the
unit doesn’t
work.
The power line and the cable locking connector is
not connecting properly.
Check the power connection with the unit is connected
properly.
The wires from the switches are disconnected or
loose.
Make sure the wires on the switches are connected
properly.
Light works,
but motor is not
turning.
The motor is defective, possible seized. Change the motor.
The thermally protected system detects if the motor
is too hot to operate and shuts the motor down.
The motor will function properly after the thermally
protected system cool down.
The motor wire is not connected.
Make sure the motor wire is plugged into the molex con-
nector.
The unit is
vibrating.
The motor is not secure in place. Tighten the motor in place.
Damaged blower wheel. Change the blower.
The hood is not secured in place. Check the installation of the hood.
The motor is
working, but the
lights are not.
Defective lightbulb. Change the lightbulb.
The lightbulb is loose. Tighten the lightbulb.
The wires on the light switch are loose.
Make sure the wires on light switch are connected
properly.