patrolseq string[120] <blank> 1/4 The patrol sequence of ePTZ. All the
patrol position indexes will be
separated by ","
patroldwelling string[160] <blank> 1/4 The dwelling time (unit: second) of
each patrol point, separated by ā€œ,ā€.
preset_i<0~19>_name string[40] <blank> 1/7 Name of ePTZ preset.
(It should be set by ePreset.cgi rather
than by setparam.cgi.)
preset_i<0~19>_pos <coordinate> <blank> 1/7 Left-top corner coordinate of the
preset.
(It should be set by ePreset.cgi rather
than by setparam.cgi.)
preset_i<0~19>_size <window size> <blank> 1/7 Width and height of the preset.
(It should be set by ePreset.cgi rather
than by setparam.cgi.)
7.35 Focus Window setting
Group: focuswindow_c<0~(n-1)> for n channel product.
PARAMETER VALUE Default SECURITY
(get/set)
DESCRIPTION
win_i0_enable <boolean> 0 4/4 Enable or disable the window.
win_i0_home FD8365:
(0~1728, 0~936)
FD8355:
(0~1088, 0~880)
FD8365:
(864, 468)
FD8355:
(544, 440)
4/4 Left-top corner coordinate of the
window.
win_i0_size FD8365:
(192~1920, 144~1080)
FD8355:
(192~1280, 144~1024)
(192x144) 4/4 Width and height of the window.