Direct current
Range Resolution Accuracy
20.00 A 0.01 A ± (2 % + 3)
200.0 A 0.1 A ± (2 % + 3)
Overload protection: 200 A
DC accuracy: After successful zero adjustment
AC voltage
Range Resolution Accuracy
2.000 V 0.001 V ± (1.0 % + 3)
20.00 V 0.01 V
200.0 V 0.1 V ± (1.0 % + 3)
600 V 1 V ± (1.2 % + 3)
Frequencyrange:45-400Hz;Overloadprotection:600V;Impedance:10MΩ
Crest Factor (CF) CF 1.0 - 2.0: + 3 % deviation
CF 2.0 - 2.5: + 5 % deviation
CF 2.5 - 3.0: + 7 % deviation
DC voltage
Range Resolution Accuracy
200.0 mV 0.1 mV ± (1 % + 8)
2.000 V 0.001 V
± (0.7 % + 3)
20.00 V 0.01 V
200.0 V 0.1 V
600 V 1 V
Overloadprotection:600V;Impedance:10MΩ