50
Resistance
Range Resolution Accuracy
200.0Ω 0.1Ω
± (1.0 % + 2)
2.000kΩ 0.001kΩ
20.00kΩ 0.01kΩ
200.0kΩ 0.1kΩ
2.000MΩ 0.001MΩ ± (1.2 % + 3)
20.00MΩ 0.01MΩ ± (1.5 % + 5)
Overload protection: 600 V
Capacitance
Range Resolution Accuracy
2.000 nF 0.001 nF ± (4 % + 10)
20.00 nF 0.01 nF
± (4 % + 5)
200.0 nF 0.1 nF
2.000µF 0.001µF
20.00µF 0.01µF
200.0µF 0.1µF
2.000 mF 0.001 mF ± 10 %
20.00 mF 0.01 mF ± 10 %
Overload protection: 600 V
Temperature
Range Resolution Accuracy
-40 to 0 °C
1 °C
± 3
>0 to +100 °C ± (1.0 % + 3)
>100 to +1000 °C ± (2.0 % + 3)
-40 to +32 °F
1 °F
± 5
>32 to +212 °F ± (1.5 % + 5)
>212 to +1832 °F ± (2.5 % + 5)