PM100/300
POWER ANALYZERS
USER MANUAL
www.voltech.com
V
oltech Instruments Inc.
11637 Kelly Road, Suite 306
Fort Myers, FL 33908
U.S.A.
Tel: 239 437 0494
Fax: 239 437 3841
sales@voltech.com
V
oltech Instruments Ltd.
148 Harwell Sience and Innovation Campus
Didcot, OX11 0RA
U.K.
Tel: +44 (0) 1235 834555
Fax: +44 (0) 1235 835016
sales@voltech.co.uk
Thank you for choosing to use this Voltech Power Analyzer.
Should you experience any difficulty during the set up or use of any
Voltech product, or are unsure of any of their features or abilities,
please do not hesitate to contact either your local supplier or one o
f
our Voltech offices.
Question and Answer IconNeed help?

Do you have a question about the Voltech PM100 and is the answer not in the manual?

Voltech PM100 Specifications

General IconGeneral
Voltage Accuracy±0.1% of reading
Current Accuracy±0.1% of reading
Power Accuracy±0.2% of reading
Accuracy±0.1% of reading
Harmonic AnalysisUp to 50th harmonic
Operating Temperature0°C to 50°C
Power Supply100-240 V AC, 50/60 Hz
Current Range20 A
DisplayLCD
InterfacesGPIB
Weight10kg

Summary

Warranty Information

Health and Safety

Electrical Shock Risk Warning

Highlights the danger of electric shock and advises user responsibility for installation compliance and qualified personnel.

Voltage Setting Check Before Connection

Instructs users to check the line input voltage setting before connecting the analyzer to the supply.

General Safety Precautions

Lists essential safety measures, including earthing, power connection order, servicing by qualified personnel, and lead condition.

Getting Started

Connecting the Analyzer Diagrams

Illustrates various connection diagrams for single-phase and three-phase measurements, including wiring modes.

Function Keys

The Menu System

Accessing Menu Options

Explains how to enter and navigate the analyzer's menu system, select menus, and change options.

M[5] Calibration Menu

Details the calibration process, including password entry and setting calibration values for voltage and current.

M[5] Calibration Process

Guides through the calibration method, including password entry, setting voltages, and entering readings.

Calibration Procedure

Voltage Calibration

Details the equipment and connections required for voltage calibration of the analyzer.

Current Calibration (Internal Shunt)

Describes the procedure for current calibration using internal shunts.

Current Calibration (External Shunt)

Details the specific setup for calibrating current using an external shunt connection.

Calibration Method Steps

Outlines the steps for calibration, including password entry, voltage/current setup, and busy status.

Calibrate Amps

Details the process for calibrating the current measurement ranges (AR1 to AR8).

Specifications

Voltage Specifications

Details voltage ranges, accuracy, crest factor, input impedance, and common mode voltage effects.

Current Specifications

Provides specifications for current ranges, accuracy (excluding neutral), crest factor, and input impedance.

Power Specifications

Details display range and accuracy for Power, Apparent Power, and Reactive Power measurements.

Power Factor and Crest Factor Specifications

Covers specifications for Power Factor range/accuracy and Crest Factor range/accuracy.

Harmonics and THD Specifications

Provides specifications for Harmonics (bandwidth, accuracy) and Total Harmonic Distortion (THD) range/accuracy.

EMC Compliance

Declaration of Conformity

Declaration by Voltech Instruments Ltd for the PM100, confirming compliance with Safety and EMC directives.

EMC Precautions

Details precautions for conducted/radiated emissions and immunity, including ferrite use and recovery from disruptions.