Ceramic Master Е1000 en v3 16
PRESS furnace.
Switch off the furnace. Keep the buttons RUN and STOP
pressed simultaneously and switch on the power
supply.
Wait for the following to appear:
STOP SOUND: YES (N0)
Press ESC button. The display will show:
CRASH TEMP LIMIT
040
Press STOP button.
Following question will appear:
Load data from PC?
The furnace prompts to enter data from the PC to the
furnace. If no entering of data is needed then press the
ESC button. If entering of data is needed then start the
program Teraterm Pro on the PC.
Go to menu SETUP/Serial Port in this program and
perform following settings:
Com x - Serial port number
Baud Rate - 9600
Data - 8 bit
Parity - none
Stop - 1 bit
Flow Control - none
Transmit Delay - 0ms 10ms
Enter the menu File/Send File and perform following
settings:
Options - select binary
Enter the file name where the programs are to be
loaded from.
Press the PROG button of the furnace.
Select the function Open from the PC.
A message on the furnace display will appear:
RECEIVING
Programs xx
This means that the programs are being loaded
currently.
After finishing following question will appear on the
display of the furnace:
Send programs to PC?
Push the ESC button .
Following question on the furnace display will appear:
Send log file to PC?
Press the ESC button.
Transfer of programs from the Ceramic Master PRESS to
PC.