CAUTION!
40 - A non-number-type symbol has appeared during
receiving.
41, 42 - A symbol is received which is not = or ~ during
receiving.
160 - Received number for the minutes greater than
59 during receiving.
161 - Received number for the seconds greater than
59 during receiving.
30; 31 - Timeout during receiving of programs
120 - ENTRYTEMP < IDLETEMP + 25
121 - ENTRYTEMP >750
122 - ENTRYTEMP<DRY2TEMP-20
123 - DRY2RATE<30 or DRY2RATE>200
124 - FIRE1RATE<30 or FIRE1RATE>200
125 - FIRE2RATE<30 or FIRE2RATE>200
126 - DRY2TEMP >FIRE1TEMP-20
127 - FIRE1TEMP >FIRE2TEMP-20
128 - FIRE2TEMP >1200
129 - COOL1TEMP<ENTRYTEMP+20
130 - COOL1TEMP>FIRE2TEMP-20
131 - VRUNTEMP>1250
132 - VSTOPTEMP>1250
133 - VACLEVEL>971
134 - VACLEVEL<100
135 - PR_RATE<20 or PR_RATE>30
When any error appears, it is written on the display and
the furnace produces a sound signal. The button STOP
has to be pressed in order to exit from this state.