Switch off the furnace. Keep the buttons RUN and STOP
pressed simultaneously and switch on the power
supply.
Wait for the following to appear:
ait to appear message:
STOP SOUND: YES (N0)
Press ESC button. The display will show:
CRASH TEMP LIMIT
040
Press STOP button.
Following question will appear:
Load data from PC?
Press the ESC button and this question will appear on
the furnace display:
Send programs to PC?
The furnace prompts to output the data from the
furnace to the PC. If this is not needed, press the ESC
button. When you wish to start transfer of data from
the furnace to the PC start the program Teraterm Pro.
Open the menu SETUP/Serial Port and perform
following settings:
Com x - Serial port number
Baud Rate - 9600
Data - 8 bit
Parity - none
Stop - 1 bit
Flow Control - none
Transmit Delay - 0ms 10ms
Go to the menu File/Log and perform following
settings:
Options - select binary
Enter the file name where the programs are to be saved
and select function Open.
Press the PROG button of the furnace.
After the end of the operation following question will
appear on thefurnace display.
Send log file to PC?
Push the ESC button.
Close the file with the programs of the computer. This is
done by going to the Teraterm Log window and pushing
the STOP button.
Transfer of a LOG file from the Ceramic Master PRESS
furnace to PC.