Ceramic Master Е1000 en v3 18
Switch off the furnace. Keep the buttons RUN and STOP
pressed simultaneously and switch on the power
supply.
Wait for the following to appear:
STOP SOUND: YES (N0)
Press ESC button. The display will show:
CRASH TEMP LIMIT
040
Press STOP button.
Following question will appear:
Load data from PC?
Press the ESC button and this question will appear on
the furnace display:
Send programs to PC?
Press the ESC button and following question will appear
on the furnace display:
Send log file to PC?
From the PC start the program Teraterm Pro.
Enter the SETUP/Serial Port menu and perform
following settings:
Com x - Serial port number
Baud Rate - 9600
Data - 8 bit
Parity - none
Stop - 1 bit
Flow Control - none
Transmit Delay - 0ms 10ms
Go to the menu File/Log and perform following
settings:
Options - binary
Enter the file name where the coded data from the
furnace to be saved and select Open.
Press the PROG button of the furnace.
After the end of the process you can continue to work
with the furnace.
Close the log file in the PC by going to the Teraterm Log
window and pressing the CLOSE button.
Reloading of the control program (flash)