5:HDI
6:multi-step speed
7:communication
8:PID
9:Internal PLC
Notice:DI terminal function code 26-32
superior than this function code
Auxiliary frequency
source selection (B)
Same as P01.00
Notice:DI terminal function code 33 superior
than this function code
Reference option for
auxiliary frequency
source
0:Relative to Maximum frequency
1:Relative to main frequency
Auxiliary frequency gains
Frequency source
selection
0:main frequency sourceA
1:auxiliary frequency sourceB
2:Main and auxiliary arithmetic results
3:Switchover between main and auxiliary
frequency
4:switchover between main frequency source
A and A+B Arithmetic results
5:Switchover between B and (A+B)
(*)DI function code 25 effective to
corresponding terminal ,frequency will adopt
the latter
Main and Auxiliary
arithmetic
0:A+B
1:A-B
2:The bigger of main A and Auxliary B
3:The smaller of Main A and Auxiliary B
4:A*B
A*B have better frequency adjustment ,wiely
used for winding industry, fine sand machine,
and leather, paper industry...