Loading...
- 51-
Functio
n code
Parameter name
Description
Default
Ineffective
effective
Ineffective
effective
Multispeed 5
Ineffective
effective
Effective
Ineffective
Multispeed 6
Ineffective
effective
Effective
effective
Multispeed 7
effective
Ineffective
Ineffective
Ineffective
Multispeed 8
effective
Ineffective
Ineffective
effective
Multispeed 9
effective
Ineffective
Effective
Ineffective
Multispeed 10
effective
Ineffective
Effective
effective
Multispeed 11
effective
effective
Ineffective
Ineffective
Multispeed 12
effective
effective
Ineffective
effective
Multispeed 13
effective
effective
Effective
Ineffective
Multispeed 14
effective
effective
Effective
effective
Multispeed 15
Priority method Description:
Multispeed
terminal 4
Multispeed
terminal 3
Multispeed
terminal 2
Multispeed
terminal 1
Priority method Speed
reference
Ineffective
Ineffective
Ineffective
Ineffective
Multispeed 0
Ineffective
Ineffective
Ineffective
effective
Multispeed 1
Ineffective
Ineffective
effective
random
Multispeed 2
Ineffective
effective
Random
random
Multispeed 3
effective
random
Random
random
Multispeed 4
P01.20
Multiple step speed
Rotation direction
Bit0 15 corresponding to 0 15 phase
direction
0:forward direction 1:reverse direction
0
P01.21
Multiple step speed
0/in-built plc 1
Lower limit frequency (P01.09) maximum
frequency(P01.06)
0.00Hz